AC/DC Switching Power Supplies

AC/DC Switching Power Supplies
Product Detailed
AC/DC Switching Power Supplies with Overload and Short-circuit Protection

Switching power supply:1, Low price and high reliability2, 105 centidegree output capacitor3, AC input power suitable for the world4, High efficiency and low operation temperature5, Soft-start current can reduce the AC input impact effectively6, With short-circuit and overload protection7, Compact size, light weight8, 100% full-load burning test

Specification

CFS-50-5

CFS-50-12

CFS-50-15

CFS-50-24

DC output voltage

5V

12V

15V

24V

Output voltage error (Note2)

±2%

±1%

±1%

±1%

Rated output current

10A

4.2A

3.4A

2.1A

Output current rage

0-10A

0-4.2A

0-3.4A

0-2.1A

Wave and noise(Note3)

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note4)

±0.5%

±0.5%

±0.5%

±0.5%

Load stability(Note5)

±1%

±0.5%

±0.5%

±0.5%

DC output power

50W

50.4W

50.4W

50.4W

Efficiency

71%

78%

78%

82%

Adjustable range for DC voltage

±10,-5%

±10%

±10%

±10%

AC input voltage range

85 to132VAC/170 to264VACselected by switch

Input current

1.3A /115V 0.65A/230V

AC impulse current

Cold-start current 18A/115V 36A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105% to150%Type TOLDBACK Reset: auto recovery

Over-voltage protection

……

High-temperature protection

……

Temperature coefficient

±0.03% centidegree (0 to50 centidegree )

Setup rise hold up time

200ms,100ms,30ms

Vibration

10 to500Hz,2G 10min./1cycle,Period for 60min,Each axes

Withstand voltage

Input and output interval 1.5KVAC , Input and enclosure 1.5KVAC , Output and enclosure 0.5KVAC

Isolation resistance

Input and output interval, Input and enclosure, Output and enclosure 0500VAC/100M Ohms

Working temperature and humidity

-10 centidegree to+60 centidegree , 20% to90%RH

Store temperature and humidity

-20 centidegree to+85 centidegree ,10% to95RH

Overall dimension

159*97*38mm

Weight

0.5Kgs

Safety standards

Meet UL1012

EMC standards

……

Note:1.The testing condition for the parameter above is:230VAC input, rated load,25 centidegree 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adopting“A12”double wire for 20MHz,and 0.1uF&uF capacitor short-ci rcuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2  3  11must be knocked down.